Beam or block floor

Incorporating precast concrete beams with lightweight concrete blocks as an infilling

Floor screed dpm and insulation

Beams or block

COncrete bed

Hardcore


  • Precast concrete beams
  1. Shaped like an inverted T in section
  2. THe depth of the beams is from 130 to 250mm
  3. THe beams are precast in lengths of up to 6m
  4. The T beams are reinforced with mild steel reinforcing bars to provide adequate support for the anticipated dead and imposed loads

  • LIghtweight concrete blocks
  1. Made to fit between and bear on the T beams
  2. Some of the blocks are hollow for lightness
  3. It is possible to use rigid insulation between the beams , instead of concrete blocks

  • Sleeper walls are built off the concrete bed to support the precast concrete T beams
  • THe precast concrete T beams are located on the external perimeter walls and internal sleeper walls
  • Lightweight concrete block are then inserted between the beams
  • A concrete toppping or screed is spread and levelled over the precast concrete untis
  • A minimum clear boid depth of 75mm is required below these floors , but it is usual practise to leace at least 150mm'
  • Ventilation of the void should be procided to dilute and prevent concentration of gases from the ground and possible leakage from pipid services